• New owner of TenK technology. The rebirth of a famous solar technology.
  • TenK site RE-Powering. Energy harvest recovery for existing arrays.

Solar built in parallel. Resilient by design.

Global RAIS® Energy & Storage Solutions builds modular, low-voltage, kit-based solar PV systems. When one cell fails, the array keeps working. That is the whole idea.

0+installations worldwide
0%more energy density than conventional PV
0kW installed per person-hour (NREL benchmark 1.6)
<3PSFrooftop load on most projects
01Technologyof 08

One bad cell shouldn’t take down the whole string.

Conventional panels wire cells in series, so a single shaded, cracked or spiked cell drags its entire group offline. Global RAIS® Smart Modules connect cells in a parallel matrix with module-integrated electronics, so each cell stands on its own. Try it.

Conventional module

Series cells, 3 bypass groups
100%module output

Each bar is one bypass group of 20 cells.

Global RAIS® Smart Module

Parallel matrix + MIE
100%module output

Damaged cells are isolated. Neighbours keep producing.

Or click any cell to damage it

Illustrative model. Global RAIS® spike testing shows about a 1.2% energy loss from a spike driven through a module, versus full group loss in a series-wired panel.

From module to grid, no single point of failure.

Serial strings fail together. Global RAIS® systems build current in parallel, through a redundant inverter bus, so one fault barely registers.

Advantages over conventional systems

Parallel cells, parallel system architecture and low-voltage DC. If a single device fails, everything else takes up the slack.

CharacteristicConventionalGlobal RAIS®
Solar cell connectionsSerialMatrix
Partial shade performancePoorExcellent
Power point trackingStringWithin module
Performance degradationHighLow
02System advantagesof 08

More power from the same square footage.

A whole-system approach: patent-protected modules, integrated racking and DC storage that is ready from day one.

Easy to install and maintain

Built to be installed by non-electricians with minimal training, which cuts labor cost on every project.

Global RAIS®3.5 kW
NREL benchmark1.6 kW
40%

Higher energy density

Modules sit closer to rooftop obstructions with minimal impact, for up to 40% more energy density.

Low voltage, lower risk

30V to 59V on the DC side. Low-voltage architecture increases safety and reduces fire hazards.

<3PSF

Lightweight integrated design

Little or no ballasting needed, so the system stays light on the roof.

Efficient DC to DC storage

Works with most 48V batteries. Voltage is factory and field settable.

Greater durability

Cell-agnostic architecture with an aluminum back sheet, minimally affected by shade, delamination or water intrusion.

The detail behind every advantage

Our Technology Overview explains the original TenK architecture that Global RAIS® now owns: parallel cell matrix, redundant inverter bus, low-voltage DC and native storage.

03The Global RAIS® Kitof 08

Module, inversion, racking. One kit.

Our ultra-safe, resilient systems ship as a complete kit and adapt to off-grid and grid-tied installations, on rooftops, ground mounts and carports.

Exploded view of the Global RAIS kit: Smart Module, module-integrated inversion and rackingDC storage ready
Global RAIS Smart ModuleDC storage ready
Global RAIS ballast-light racking in an east-west array
DC battery storage cabinets

Everything in the box, engineered together

Module, module-integrated inversion and racking are designed as one system, which is why install rates beat conventional solar by more than double.

  • Off-grid and grid-tied ready
  • Rooftop, ground mount and carport applications
  • DC storage ready out of the box

Patented Smart Module architecture

Parallel, or matrix, cell connections enable cell-independent performance. Module-integrated electronics (MIE) turn each panel into a Smart Module.

  • Power point tracking within the module
  • About 1.2% loss from a spike through the module
  • Impact-resistant glass, aluminum back sheet

Proprietary parallel system architecture

Current builds in parallel, not series. If a single device fails, the rest of the system takes up the slack with only a minimal drop in output.

  • No single point of failure across strings
  • Redundant Inverter Bus
  • Virtually eliminates complete system failure

Ballast-light, non-penetrating racking

An integrated, aerodynamic design normalizes wind pressure across the array, so most projects need little or no ballast.

  • Under 3 PSF on most rooftops
  • Delta Rail and Tubular Rail ground mounts
  • Non-penetrating options

DC to DC efficient storage

Battery storage integrates naturally because the array is low-voltage on the DC side. The battery controls line voltage while the panels supply charging current.

  • Charging range of 30V to 59V
  • Fits most 48V battery storage units
  • Factory and field-settable voltage
04Projectsof 08

2,900+ installations. Here are a few.

P/01
Commercial rooftop

Mandalay Bay, Las Vegas

P/02
RE-Powered
2.7 MW parking ramp

Minneapolis Airport

P/03
Commercial rooftop

Albertville FMC

P/04
Commercial rooftop

Mass American, Geriatric facility

P/05
Ground mount

10K DUO Ground Mount

P/06
Commercial rooftop

Mass American, Park Ridge

Commercial rooftop

Dense, ballast-light arrays

Ground mount

Delta Rail and Tubular Rail

Carport

Shade plus generation

05Newsof 08

Latest from Global RAIS.

Press coverage, RE-Powering field results, our newsletter and new technical resources.

Get the Global RAIS® newsletter for TenK owners.

06About usof 08

Balancing profit and purpose.

Headquartered in Huntsville, Alabama, we are committed to a better world through sustainable technology, growth and opportunity: in what we build for customers, the jobs we create, and our impact on the economy and environment.

We design

Patented module and system architecture engineered around one question: what happens when something fails?

We manufacture

Kit-based systems built to be installed quickly and safely, by crews of every experience level.

We support

Data sheets, install manuals and white papers, plus a team that picks up the phone.

Global RAIS® rooftop installation

Our pursuit of B Corp certification reflects our values

  • 01Contribute to an ethical and green supply chain
  • 02Build an inclusive, sustainable economy through responsible growth
  • 03Create verifiable social and environmental performance goals
  • 04Provide high-quality jobs in an inclusive, diverse and equitable work culture
GC

Gregory Cox, MS

Co-Founder, CEO

Experienced manager with hands-on expertise in solar PV and storage design for distributed energy systems.

TB

Todd Broome, MD

Co-Founder

Practicing physician and successful commercial real estate owner and developer.

07Specs & supportof 08

Everything your engineer will ask for.

White papers, product data sheets and installation manuals. Download what you need, or ask us for something specific.

Put more power on the same roof.

Send us your site, load and storage goals. Our engineers will come back with a system design and estimate.

08Contactof 08

Let’s size your system.

Interested in Global RAIS® or how an installation can benefit your project? Tell us a little and we’ll be in touch.

Location
2601 Triana Blvd. SW
Huntsville, AL 35805
Mail
P.O. Box 7247
Huntsville, AL 35807-1247